MOQ : 1 Piece

FLUKE 51-II Specification

  • Accuracy
  • (0.05% + 0.3C) (above -100C)
  • Display Type
  • Digital LCD
  • Resolution
  • 0.1C/0.2F
  • Equipment Type
  • Digital Thermometer
  • Operating Voltage
  • 9V
  • Humidity
  • 0% to 90% RH (non-condensing, up to 35C)
  • Power Supply
  • Single 9V battery
  • Test Range
  • -50C to 400C (-58F to 752F)
  • Response Time
  • < 2.5 seconds
  • Temperature
  • Operating: -10C to 50C; Storage: -40C to 60C
  • Application
  • Industrial temperature measurement
  • Measuring Range
  • -50C to 400C (-58F to 752F)
  • Mounting Type
  • Handheld
  • Features
  • Data Hold, MIN/MAX/AVG recording, calibration through front panel, selectable C/F, easy single input
  • Interface Type
  • Thermocouple (K-type input)
  • Automation Grade
  • Manual
  • Usage
  • Temperature measurement
  • Machine Weight
  • 0.21 kg (including battery)
  • Control Mode
  • Manual
  • Display Backlight
  • Yes
  • Compliance
  • CE, CSA
  • Calibration
  • User calibration through front panel
  • Battery Life
  • Up to 1000 hours (alkaline battery)
  • Dimensions
  • 173 mm 86 mm 38 mm
  • Input Types Supported
  • K-type (optional J-type, T-type or E-type thermocouples with adapter)
 

FLUKE 51-II Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Delivery Time
  • 2 Days
 

About FLUKE 51-II

Key Features

  • Single Input digital thermometer for lab, QA, process calibration, food safety and HVAC
  • Measures J, K, T, and E-type thermocouples
  • Presents results in C, F, or Kelvin (K) on a large backlit display
  • Includes a relative time clock on MIN, MAX, and AVG to provide a time reference for major events


Comprehensive Temperature Measurement

The FLUKE 51-II offers a versatile solution for accurate temperature monitoring, accepting K-type thermocouples by default and supporting others with optional adapters. Covering a broad test range and high accuracy, this device fits various industrial applications, offering dependable performance in demanding environments.


Effortless Calibration and Operation

Calibration is straightforward thanks to the user calibration function accessible through the front panel. The single-button controls, selectable Celsius/Fahrenheit modes, and useful features like Data Hold and MIN/MAX/AVG recording make operation and data logging intuitive for technicians and engineers alike.


Designed for Industrial Durability

This digital thermometer is built to withstand challenging conditions, with a rugged casing, compliance with CE and CSA standards, and an ability to operate efficiently in a wide range of temperatures and humidity levels. Its extended battery life and compact design make it portable and long-lasting for field and industrial use.

FAQ's of FLUKE 51-II:


Q: How do I calibrate the FLUKE 51-II thermometer?

A: Calibration for the FLUKE 51-II is performed via the front panel, allowing users to maintain measurement accuracy without specialized tools or returning the unit for service.

Q: What types of thermocouples does the FLUKE 51-II support?

A: The FLUKE 51-II supports K-type thermocouples as standard, and also accommodates J-type, T-type, or E-type thermocouples when used with an appropriate adapter.

Q: Where can the FLUKE 51-II be used effectively?

A: This digital thermometer is ideal for industrial settings such as manufacturing, HVAC, and laboratory environments, thanks to its durability, wide operating range, and precise measurements.

Q: What is the battery life and how is the device powered?

A: The FLUKE 51-II operates on a single 9V alkaline battery, providing up to 1000 hours of operation for extended fieldwork or continuous monitoring tasks.

Q: What benefits does the large digital backlit LCD provide?

A: The backlit LCD ensures clear and easy-to-read measurements, even in low-light conditions, enhancing usability across various workspace settings.

Q: How quickly does the FLUKE 51-II display temperature readings?

A: With a response time of less than 2.5 seconds, users can obtain fast and accurate temperature readings, streamlining measurement processes in time-sensitive tasks.

Q: What safety and compliance standards does the FLUKE 51-II meet?

A: The device adheres to both CE and CSA safety standards, offering reliable and certified performance for industrial professionals.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Infrared Thermometer Category

FLUKE 52-II

FLUKE 52-II

Price 60000.0 INR / Piece

Minimum Order Quantity : 1 Unit

Features : Min/Max/Avg/Differential readings, Data hold, Auto poweroff, Calibration function

Accuracy : (0.05% + 0.3 C)

Power Supply : 3 AA batteries

Usage : Contact temperature measurement

FLUKE 53-II

FLUKE 53-II

Price 59999.0 INR / Unit

Minimum Order Quantity : 1 Unit

Features : Data Logging, MIN/MAX/AVG, Hold, Realtime Clock, Time Stamps, Backlight

Accuracy : (0.05% + 0.3C) typ. (for Ktype, 40C to 1200C)

Power Supply : 3 x AA Alkaline Batteries

Usage : Temperature Measurement

FLUKE 54-II

FLUKE 54-II

Price 60000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Features : Differential temperature measurements, dual input, data logging

Accuracy : (0.05%+0.3 C)

Power Supply : Three AAA batteries

Usage : Industrial and laboratory temperature monitoring

IR Thermometer Gun

IR Thermometer Gun

Price 2500 INR / Unit

Minimum Order Quantity : 1 Unit

Features : Stable operation

Accuracy : +1 C

Power Supply : Battery

Usage : NonContact/Medical



Back to top